{"en":"NECMSeries Evaporative Condenser","zh-cn":"NECN逆流式蒸发冷凝器"}

NECN逆流式蒸发冷凝器

NECN逆流式蒸发冷凝器

一种高效逆流式蒸发冷凝器。用于替代传统主机+冷却塔的冷凝方式。省去壳管式换热器/板式换热器。直接喷淋冷却,结构简单高效。适用于直接接触冷凝R717R22R407R410, R134等冷媒和其他气液体冷却。
 

特点
逆流式结构,无填料设计

盘管喷淋式设计

不锈钢材质盘管,耐腐蚀,可侵泡清洗

设计紧凑,支持整装发货和半整装发货

♦模块化设计,满足大容量扩展

主要材料

壳身,Z-700镀锌钢/304不锈钢
盘管,304无缝不锈钢加工成型
喷淋泵,专用大流量低杨程喷淋泵
风机和驱动系统,高效铝合金风扇,IP55电机,IE3能效
进风格栅,采用EVL进风格栅
收水器,EVD高效收水器,除水效率99.99%

功能选项

电子除垢器
水盆加热防冻功能
VFD变频控制器
外部检修平台和护栏
 
Technical Specification of NECM Series Cooling Tower
 
 Item Heat 
Rejection
Capacity 
(KW)
Dimension (mm) Axial Fan Spray Pump NH3 
 Ammonia 
Charge 
 (kg)
Weight (kg)
 Model Length Width Height Air 
Volume  
(m³/h)
Power 
(Kw)xQty
Flow
 (m³/h)
Power 
(Kw)
Dry Wet
NECM-40 40 1150 900 1920 10500 0.55 14 0.75 8 350 600
NECM-64 64 1150 1150 1920 13050 0.75 14 0.75 9 400 700
NECM-80 80 2000 1150 2200 26100 0.75*2 30 1.1 11 520 1000
NECM-120 120 2000 1150 2200 26100 0.75*2 30 1.1 13 570 1100
NECM-160 160 2500 1150 2200 36600 1.1*2 40 1.5 18 650 1600
NECM-200 200 2500 1150 2350 36600 1.1*2 40 1.5 28 750 1700
NECM-280 280 2500 1400 2650 40600 1.5*2 40 1.5 41 850 1800
NECM-320 320 2500 1400 2650 40600 1.5*2 60 1.5 43 1050 2000
NECM-400 400 2500 1400 2650 46900 2.2*2 60 1.5 45 1250 2300
NECM-480 480 2500 1400 2650 53000 2.6*2 60 1.5 65 1350 2400
NECM-560 560 3000 1400 2850 63800 3.5*2 65 2.2 65 1650 3000
NECM-640 640 3000 1400 2850 90000 4*2 65 2.2 81 1850 3300
NECM-800 800 3000 2180 2850 90000 4*2 110 3 83 2050 3800
NECM-1000 1000 3518 2180 3250 110000 5.5*2 110 3 109 2450 4300
NECM-1200 1200 3518 2180 2850 150000 7.5*2 110 3 120 3150 4300
NECM-1400 1400 4010 2980 3910 180000 7.5*2 170 5.5 142 3700 7100
NECM-1600 1600 4010 2980 3910 220000 7.5*2 170 5.5 166 4180 7600
NECM-2000 2000 4510 2980 3910 300000 11*2 170 5.5 220 5050 8900
NECM-2400 2400 7036 2180 2850 300000 7.5*4 220 3*2 237 6300 8600
NECM-2800 2800 8020 2980 3910 360000 7.5*4 340 5.5*2 283 7400 14200
NECM-3200 3200 8020 2980 3910 440000 7.5*4 340 5.5*2 330 8360 15200
NECM-4000 4000 8020 2980 3910 600000 11*4 340 5.5*2 438 10100 17800
 
 Instructions for Selection
 1. Confirm condensing temperature, wet bulb temperature.
 2. Calculate total heat abstraction amount that goes through system to condensers.
 3. Take a reference to below Graph 1 or Graph 2, select heat abstraction amount correction index.
 4. Total amount of heat abstraction multiplies heat correction index equals to the condensing load during the working
 conditions.
 5. Take a reference to Graph Specification sheet, select the heat abstraction amount data which is bigger or equivalent to
the data after correction.


Gragh 1: Heat Emission Correction Index for R717
 
Condensing
Pressure
(Kpa)
Condensing
Temp.
(°C)
Air Inlet Wet Bulb Temp. (°C)
18 19 20 21 22 23 24 25 26 27 28 29 30
1063 30 1.40  1.51  1.63  1.79  1.99  2.24  2.56  3.00           
1133 32 1.18  1.25  1.32  1.43  1.55  1.70  1.88  2.11           
1206 34 1.02  1.07  1.12  1.19  1.28  1.36  1.48  1.61  1.80  2.06       
1245 35 0.95  0.99  1.03  1.08  1.15  1.23  1.30  1.39  1.53  1.69  1.90  2.15  2.47 
1284 36 0.89  0.92  0.96  1.01  1.07  1.13  1.20  1.28  1.39  1.53  1.70  1.91  2.17 
1365 38 0.78  0.81  0.83  0.86  0.90  0.94  0.99  1.05  1.12  1.21  1.31  1.44  1.59 
1451 40 0.70  0.72  0.74  0.76  0.80  0.83  0.87  0.91  0.96  1.02  1.09  1.18  1.29 
1530 42 0.63  0.64  0.66  0.68  0.71  0.74  0.76  0.80  0.84  0.88  0.93  0.99  1.06 
1630 44 0.56  0.58  0.59  0.61  0.63  0.65  0.67  0.70  0.76  0.76  0.79  0.83  0.86 

请确保您的联系信息正确。 您的消息将直接发送给我们,并且不会公开显示。 未经您的明确许可,我们绝不会将您的个人信息分发或出售给第三方。